TR 61/62 uses Pt100 probes with a measuring range of -148 to +752 °F (-100 to 400 °C) and an accuracy of ±0.4% of reading ±0.55 °F (±0.3 °C).

Probe(s) not included, sold separately.



 [  Technical Data sheet ](https://www.kimo-instruments.com/sites/default/files/files/DS_portable-TR61-TR62_EN-US_01-10-24.pdf) 

 

       TR 61: 1 channel and TR 62: 2 channels 

 

       Measuring range: -148 to +752 °F (-100 to 400 °C) 

 

       Adjustable alarms 

 

       Adjustable backlight 

 

       Hold function and min-max values 

 

       Adjustment certificate 

 

 

 

 


 Product info   #### Measure details

- Units
    
     
    
    °F, °C
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

#### Measuring ranges

- Pt100 probe
    
     
    
    -100.00 °C ... 400.00 °C
- Pt100 probe
    
     
    
    -148.00 °F ... 752.00 °F
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

 



 

 

#### Technical details

- Parameters
    
     
    
    Temperature
- Displays
    
     
    
    4-line display
- IP Protection
    
     
    
    IP 54
- Battery life
    
     
    
    180 hours
- Standards
    
     
    
    FCC part 15
    
    UKCA
    
    2011/65/EU RoHS II
    
    2012/19/EU WEEE
    
    2014/30/EU EMC
    
    2014/35/EU Low Voltage
- Power supply
    
     
    
    4 batteries AAA LR03 1.5 V
- Protective cover
    
     
    
    No
- Interchangeable module
    
     
    
    No
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

#### Instrument Dimensions

- Length
    
     
    
    5 13/16 inches
- Width
    
     
    
    3 1/32 inches
- Height
    
     
    
    1 11/32 inches
- Weight
    
     
    
    15/32 pounds
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

#### Operating temperature

- Min
    
     
    
    0.00 °C
    
    32.00 °F
- Max
    
     
    
    50.00 °C
    
    122.00 °F
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

#### Storage temperature

- Min
    
     
    
    -20.00 °C
    
    -4.00 °F
- Max
    
     
    
    80.00 °C
    
    176.00 °F
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 



 Probes   [ ![sondes thermo](/sites/default/files/styles/small/public/images/sondes-thermo_0_1.jpg.webp?itok=SllhQ9dM)

 Thermocouple and Pt100 temperature probes](/en-US/measuring-instruments/portable-instruments/probes/thermocouple-and-pt100-temperature-probes)

[ ![Boule noire](/sites/default/files/styles/small/public/images/Boule_noire_150mm-seule.png.webp?itok=m8I03I2t)

 Black ball thermometer](/en-US/measuring-instruments/portable-instruments/probes/black-ball-thermometer)

 

 

 Accessories    [ ![cq 15](/sites/default/files/styles/small/public/images/cq15.jpg.webp?itok=nabnpCX_)

 Protective cover CQ 15 ](/en-US/measuring-instruments/portable-instruments/accessories/protective-cover-cq-15)

 [ ![rte](/sites/default/files/styles/small/public/images/rte.jpg.webp?itok=1IuTru8s)

 Telescopic extension RTE ](/en-US/measuring-instruments/portable-instruments/accessories/telescopic-extension-rte)

 

 

 Compliance