[![Sauermann Si-CA 230](/sites/default/files/styles/product_image/public/images/230-COMPO-LEFT.png?itok=YP5NuR-g)](https://www.kimo-instruments.com/sites/default/files/styles/max_1300x1300/public/images/230-COMPO-LEFT.png?itok=k_Jg2D1V)

[![TUV](/sites/default/files/styles/thumbnail/public/images/Logo_FW11_4c_EN_50379_1.png?itok=jSipwiJB)](https://www.kimo-instruments.com/sites/default/files/styles/max_1300x1300/public/images/Logo_FW11_4c_EN_50379_1.png?itok=QJff4h0X)

[![Si-CA 230](/sites/default/files/styles/thumbnail/public/images/230-FRONT.png?itok=NhLdWMCu)](https://www.kimo-instruments.com/sites/default/files/styles/max_1300x1300/public/images/230-FRONT.png?itok=VboxDlOO)

[![Si-CA 230](/sites/default/files/styles/thumbnail/public/images/Si-CA-230-APPLICATION-2_low.jpg?itok=oi2aQNhE)](https://www.kimo-instruments.com/sites/default/files/styles/max_1300x1300/public/images/Si-CA-230-APPLICATION-2_low.jpg?itok=q4Gl9MC2)

[![Si-CA 230](/sites/default/files/styles/thumbnail/public/images/Si-CA230-BOILER-2_Low.jpg?itok=zeuqo7ZS)](https://www.kimo-instruments.com/sites/default/files/styles/max_1300x1300/public/images/Si-CA230-BOILER-2_Low.jpg?itok=NGLzlEUm)

[![Si-CA 230](/sites/default/files/styles/thumbnail/public/images/Si-CA230-BOILER-1_Low.jpg?itok=AXCCT52z)](https://www.kimo-instruments.com/sites/default/files/styles/max_1300x1300/public/images/Si-CA230-BOILER-1_Low.jpg?itok=Otwu6a69)

[![Si-CA 230](/sites/default/files/styles/thumbnail/public/images/Si-CA-230-APPLICATION-1_Low.jpg?itok=XVuufGQx)](https://www.kimo-instruments.com/sites/default/files/styles/max_1300x1300/public/images/Si-CA-230-APPLICATION-1_Low.jpg?itok=21FaBVx1)

 

 

 

 

With double the number of cells and expanded measurement capabilities, the Si-CA 230 is suited to the most powerful industrial machines. And with support for more gases and a high CO tolerance threshold, its versatility makes it the ideal choice across residential, commercial and industrial applications.



 [  Technical Data sheet ](https://www.kimo-instruments.com/sites/default/files/files/DS_Si-CA230_25-08-25_EN.pdf) [  User manual ](https://www.kimo-instruments.com/sites/default/files/files/UM_Si-CA230_17-03-26_EN.pdf) [  Simplified manual ](https://www.kimo-instruments.com/sites/default/files/files/QSG-Commercial-Industrial-HVAC-Analyzers_2021-Si-CA130-230_04-10-24.pdf) 

 

       Up to six gas sensors 

 

       Total NOx &amp; Low NOx Capable 

 

       Field Replaceable Pre-Calibrated Sensors 

 

       Large Color Touch Screen 

 

       iOS and Android Mobile Apps for Real-Time Display &amp; Control 

 

       CO Dilution auto-range with measurements to 50,000 ppm 

 

 

 

 


 Product info   #### Measure details

- Units
    
     
    
    °C, %, Pa, ppm, m/s, mbar
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

#### Measuring ranges

- O2
    
     
    
    0.00 % ... 25.00 %
- CO (H2 comp.)
    
     
    
    0.00 ppm ... 10000.00 ppm
- CO (with dilution)
    
     
    
    100.00 ppm ... 50000.00 ppm
- CO2
    
     
    
    0.00 % ... 99.00 %
- NO
    
     
    
    0.00 ppm ... 5000.00 ppm
- Low NO
    
     
    
    0.00 ppm ... 300.00 ppm
- NO2
    
     
    
    0.00 ppm ... 1000.00 ppm
- Low NO2
    
     
    
    0.00 ppm ... 100.00 ppm
- NOx
    
     
    
    0.00 ppm ... 7500.00 ppm
- Low NOx
    
     
    
    0.00 ppm ... 450.00 ppm
- SO2
    
     
    
    0.00 ppm ... 5000.00 ppm
- Low SO2
    
     
    
    0.00 ppm ... 100.00 ppm
- CxHy (HC)
    
     
    
    0.00 % ... 5.00 %
- H2S
    
     
    
    0.00 ppm ... 500.00 ppm
- Flue temperature
    
     
    
    -20.00 °C ... 1250.00 °C
- Air temperature
    
     
    
    -20.00 °C ... 120.00 °C
- Differential temperature
    
     
    
    0.00 °C ... 1250.00 °C
- Pressure/Draft
    
     
    
    -200.00 mbar ... 200.00 mbar
- High accuracy draft
    
     
    
    500.00 Pa ... 500.00 Pa
- Excess air
    
     
    
    0.00 % ... 999.00 %
- Efficiency
    
     
    
    0.00 % ... 100.00 %
- Efficiency (condensation)
    
     
    
    0.00 % ... 125.00 %
- Stack Gas velocity
    
     
    
    0.00 m/s ... 99.00 m/s
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 



 

 

#### Technical details

- Parameters
    
     
    
    Air quality
    
    Gas analysis
    
    CO
    
    CO₂
    
    H₂S
    
    NO
    
    NO₂
    
    O₂
    
    SO₂
- Displays
    
     
    
    Color graphical display
- IP Protection
    
     
    
    IP 42
- Battery life
    
     
    
    8 hours
- Standards
    
     
    
    2015/863 EU (RoHS 3)
    
    TÜV SÜD Certification
    
    UKCA
    
    NF EN 50379-1
    
    NF EN 50379-2
    
    2014/53/EU RED
- Wireless connection
    
     
    
    1
- Power supply
    
     
    
    Rechargeable battery, Li-Ion 5100 mA/h 3.6 V
- Usb
    
     
    
    Yes
- Sensors
    
     
    
    CO
    
    CO2
    
    CxHy
    
    H2S
    
    NOx
    
    NO
    
    NO2
    
    O2
    
    SO2
- Auto zero
    
     
    
    Yes
- Printer
    
     
    
    Remote
- Sensor protection
    
     
    
    Sensor protection by pump stopping
- Mobile application
    
     
    
    Yes
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

#### Instrument Dimensions

- Length
    
     
    
    112 mm
- Width
    
     
    
    55 mm
- Height
    
     
    
    280 mm
- Weight
    
     
    
    825 g
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

#### Operating temperature

- Min
    
     
    
    -5.00 °C
- Max
    
     
    
    45.00 °C
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 

#### Storage temperature

- Min
    
     
    
    -20.00 °C
- Max
    
     
    
    50.00 °C
 
 ![shadow](/themes/custom/kimo/images/divider-big.png) 

 



 Probes   [ ![Si-CA 180 mm probe](/sites/default/files/styles/small/public/images/PROBE-180-FRONT-1.png.webp?itok=QsjJl3yZ)

 Probes 27532, 27533, 27534](/en-INT/measuring-instruments/combustion/probes/probes-27532-27533-27534)

[ ![Si-CA probe 300 mm](/sites/default/files/styles/small/public/images/PROBE-300-2_0.png.webp?itok=SpCMjL73)

 Si-CA 230 probes](/en-INT/measuring-instruments/combustion/probes/si-ca-230-probes)

[ ![draft probe](/sites/default/files/styles/small/public/images/27544_DRAFT-PROBE.png.webp?itok=uAq7UwpO)

 Draft probe](/en-INT/measuring-instruments/combustion/probes/draft-probe)

[ ![Smart air temperature probe](/sites/default/files/styles/small/public/images/sak150-seule.png.webp?itok=Hc67mTJc)

 Smart air temperature probe](/en-INT/measuring-instruments/combustion/probes/smart-air-temperature-probe)

[ ![CO probe](/sites/default/files/styles/small/public/images/SONDE-CO_0.jpg.webp?itok=oefsxYJK)

 CO ambient probe](/en-INT/measuring-instruments/combustion/probes/co-ambient-probe)

[ ![CO2 probe](/sites/default/files/styles/small/public/images/SONDE-CO2_0.jpg.webp?itok=UpZX8wwT)

 CO2 ambient probe](/en-INT/measuring-instruments/combustion/probes/co2-ambient-probe)

 

 

 Supplied with   1 Si-CA 230 analyzer

1 O2 gas sensors 

1 CO gas sensors

1 CO Dilution Auto-Range to 50,000 ppm

1 Protective rubber holster

1 300 mm flue gas probe with 3 m dual hose (other probe lengths available)

1 Water trap with filter

1 AC power supply / charger

1 USB cable

1 Mobile app &amp; PC software

1 Internal wireless communication module

1 Carrying case

1 Quick Start Guide

1 Calibration certificate

 

 

 Accessories    [ ![printer](/sites/default/files/styles/small/public/images/PRINTER-web.jpg.webp?itok=TarEmyjy)

 Remote wireless printer ](/en-INT/measuring-instruments/combustion/accessories/remote-wireless-printer)

 [ ![sensor](/sites/default/files/styles/small/public/images/xx_SENSOR_3.png.webp?itok=w2es2d9c)

 NO or Low NO sensor for NOx ](/en-INT/measuring-instruments/combustion/accessories/no-or-low-no-sensor-nox)

 [ ![sensor](/sites/default/files/styles/small/public/images/xx_SENSOR_1.png.webp?itok=Xn3b-jyr)

  NO2 or Low NO2 sensor ](/en-INT/measuring-instruments/combustion/accessories/no2-or-low-no2-sensor)

 [ ![sensor](/sites/default/files/styles/small/public/images/xx_SENSOR_2.png.webp?itok=uBQrhvQm)

 SO2 or Low SO2 sensor ](/en-INT/measuring-instruments/combustion/accessories/so2-or-low-so2-sensor)

 [ ![sensor](/sites/default/files/styles/small/public/images/xx_SENSOR_0.png.webp?itok=wlQS9gLY)

 CxHy sensor ](/en-INT/measuring-instruments/combustion/accessories/cxhy-sensor)

 [ ![sensor](/sites/default/files/styles/small/public/images/xx_SENSOR.png.webp?itok=3fa7JQOW)

 H2S sensor ](/en-INT/measuring-instruments/combustion/accessories/h2s-sensor)

 [ ![sensor](/sites/default/files/styles/small/public/images/xx_SENSOR_5.png.webp?itok=Iapm5Ovj)

 O2 sensor ](/en-INT/measuring-instruments/combustion/accessories/o2-sensor)

 [ ![sensor](/sites/default/files/styles/small/public/images/xx_SENSOR_6.png.webp?itok=JnylStfM)

 CO or CO-H2 sensor ](/en-INT/measuring-instruments/combustion/accessories/co-or-co-h2-sensor)

 [ ![Hose extension](/sites/default/files/styles/small/public/images/EXENSION-CABLE.jpg.webp?itok=_9mKlkAu)

 Hose extension ](/en-INT/measuring-instruments/combustion/accessories/hose-extension)

 [ ![kit-etancheite](/sites/default/files/styles/small/public/images/kit-echancheite-KEG3.png.webp?itok=XHhUCvjn)

 Gas network tightness kit ](/en-INT/measuring-instruments/combustion/accessories/gas-network-tightness-kit)

 [ ![Differential pressure hose kit](/sites/default/files/styles/small/public/images/27538_DP-HOSE-KIT.jpg.webp?itok=aa3GDbHx)

 Differential pressure hose kit ](/en-INT/measuring-instruments/combustion/accessories/differential-pressure-hose-kit)

 [ ![Manual smoke pump kit](/sites/default/files/styles/small/public/images/11994_Smoke-Pump-Kit_PMO.jpg.webp?itok=Ek7f-cy3)

 Manual smoke pump kit ](/en-INT/measuring-instruments/combustion/accessories/manual-smoke-pump-kit)

 [ ![SCU sample conditioning unit](/sites/default/files/styles/small/public/images/SCU_0.png.webp?itok=JDUQWf48)

 SCU (Sample Conditioning Unit) ](/en-INT/measuring-instruments/combustion/accessories/scu-sample-conditioning-unit)

 

 

 Software   [ ![Appli Sauermann Combustion](/sites/default/files/styles/small/public/images/APP-030-130-FRONT_0.png.webp?itok=lzhS3-cA)

 Mobile app Sauermann Combustion](/en-INT/measuring-instruments/combustion/software/mobile-app-sauermann-combustion)

[ ![Logiciel Sauermann Combustion](/sites/default/files/styles/small/public/images/si-capcsoftware20121-valeurs.png.webp?itok=v6E6wokp)

 Sauermann Combustion Software](/en-INT/measuring-instruments/combustion/software/sauermann-combustion-software)

 

 

 Downloads   #### Documents

 [    Si-CA 030/130/230 selection guide](/sites/default/files/files/Gas-Analyzers-Selection-Guide-2021-04_EN_0.pdf) [    Combustion gas analyzers Si-CA 030 / 130 / 230](/sites/default/files/files/EN-INT_COMBUSTION-BROCHURE_03-25-V1-Web.pdf) [    Troubleshooting - Combustion efficiency](/sites/default/files/files/Troubleshooting-Combustion-efficiency_Si-CA_EN_0.pdf) 





 Warranty    [Warranty Policy](/en-INT/warranty-policy-si-ca-030130230-combustion-analyzers)

 Compliance