##  [ISO 14644 airflow tests in clean room](/en-AU/solutions/iso-14644-airflow-tests-clean-room) 

 ![ISO 14644 Sauermann](/sites/default/files/entityone_paragraphs/images/SOLUTION-22_Intro_468x468.png)

 

 

## Particle cleanliness of controlled atmosphere zones

Clean rooms are controlled environments where air quality is a critical parameter, regulated by the ISO 14644 standard. Controlling aeraulic parameters (pressure, velocity, flow) is essential to guarantee the cleanliness of these sensitive areas.

Whether for classification, regular checks, after a failure or a modification of the premises, a large number of measurements must be taken in clean rooms. For one-off and permanent checks, Sauermann has a lot of cutting-edge solutions for measuring air pressure, velocity and airflow.

## Parameters to be monitored

- **Pressure**
- **Velocity**
- **Airflow**



 

 

 

 

 
   Protection against contamination    ## Protection against contamination

In order to prevent the spread of particles between zones, air pressure control is essential. According to the recommendations of ISO 14644, the differential pressure must be greater than 15 Pa between two differently classified zones.

The tests to be carried out involve the use of micromanometers with a maximum permissible error (MPE) of ±2 Pa or ±0.5% of the measured value. The Kimo 210 and 310 series aeraulic devices are equipped with pressure modules that can achieve a level of precision of ±0.2% Vm ±0.8 Pa over the range -100 to +100 Pa.



 [All our portable instruments](/en-AU/measuring-instruments/portable-instruments)

 

  [ read more about AMI 310 ](/en-AU/measuring-instruments/portable-instruments/multifunctions/ami-310) [![ami310](/sites/default/files/styles/medium/public/images/ami310.jpg?itok=hqLZSHF6)](/en-AU/measuring-instruments/portable-instruments/multifunctions/ami-310)

#### AMI 310

Multifunction

Kimo’s AMI 310 measures simultaneous parameters including pressure, temperature (Pt100 and thermocouple), humidity, air quality (CO/CO2), air velocity, airflow (vane probes and hotwire), and tachometry.



 

 [ read more about MP 210 ](/en-AU/measuring-instruments/portable-instruments/micromanometers/mp-210) [![mp210](/sites/default/files/styles/medium/public/images/mp210.jpg?itok=0-0vaS0K)](/en-AU/measuring-instruments/portable-instruments/micromanometers/mp-210)

#### MP 210

Micromanometer

Kimo’s MP 210 micromanometer measures pressure, air velocity, airflow, temperature, tachometry, gas leak and carbon monoxide (up to 6 simultaneous measurements).



 

 [ read more about Pressure module ](/en-AU/measuring-instruments/portable-instruments/probes/pressure-module) [![Module-pression](/sites/default/files/styles/medium/public/images/mod_pression.jpg?itok=jjuMQ3Gc)](/en-AU/measuring-instruments/portable-instruments/probes/pressure-module)

#### Pressure module

For class 210 / 310 multi-function portables

Kimo's pressure measuring modules consist of two pressure inputs and one thermocouple input. There are five models available.



 



      ![AMI 310 Kimo](/sites/default/files/styles/max_1300x1300/public/images/SOLUTION-22_Produits-01_699x393.png?itok=qXfvjyJ7) 

 

 

 



    Flow efficiency    ## Flow efficiency

In laminar flow rooms, air speed is crucial for keeping the area clean. It is generally between 0.3 and 0.45 m/s for efficient particle sweeping. Tests using a hot-wire probe (SFC300 / SFC900) should be carried out at different points.

The ISO 14644 standard prescribes a minimum number of measuring points depending on the size of the measurement area. It is recommended that the various average time values be recorded. With their hot-wire probes, accessories and user-friendly menus, Kimo portable devices meet all the requirements for the tests to be carried out.



 [All our portable instruments](/en-AU/measuring-instruments/portable-instruments)

 

  [ read more about VT 210 ](/en-AU/measuring-instruments/portable-instruments/multifunctions/vt-210) [![vt210](/sites/default/files/styles/medium/public/images/vt210.jpg?itok=9VeIq4pr)](/en-AU/measuring-instruments/portable-instruments/multifunctions/vt-210)

#### VT 210

Thermo-hygrometer-anemometer

Specially designed for the control of ventilation systems, the VT 210 allows users to measure the air velocity, the airflow and the temperature in ducts.



 

 [ read more about HQ 210 ](/en-AU/measuring-instruments/portable-instruments/multifunctions/hq-210) [![HQ210](/sites/default/files/styles/medium/public/images/hq210.jpg?itok=ilkfC0Tn)](/en-AU/measuring-instruments/portable-instruments/multifunctions/hq-210)

#### HQ 210

Thermo-hygrometer - Air quality

The Kimo HQ 210, with its climatic condition module, measures CO2, humidity and temperature.



 

 [ read more about Omnidirectional probe SOM 900 ](/en-AU/measuring-instruments/portable-instruments/probes/omnidirectionnel-probe-som-900) [![sonde-omni](/sites/default/files/styles/medium/public/images/omni.jpg?itok=cqk76OBI)](/en-AU/measuring-instruments/portable-instruments/probes/omnidirectionnel-probe-som-900)

#### Omnidirectional probe SOM 900

For class 210 / 310 multi-function portables

Kimo`s stainless steel omnidirectional telescopic probes measure air velocity, hygrometry and temperature.



 



      ![Kimo air velocity](/sites/default/files/styles/max_1300x1300/public/images/SOLUTION-22_Produits-02_699x393.png?itok=fB-LJ9Ny) 

 

 

 



    Appropriate air renewal    ## Appropriate air renewal

The air change rate is a key factor that is controlled by accurately measuring the air flow. This factor must be checked by an electronic flow meter such as a balometer, so that it can be easily adapted to all types of vent profiles.

With its five interchangeable hoods of different sizes, the DBM 620 from Sauermann is the ideal tool for carrying out complete surveys. Capable of directly calculating the air change rate, it also measures other important cleanroom parameters such as temperature, humidity and atmospheric pressure.



 [All our portable instruments](/en-AU/measuring-instruments/portable-instruments)

 

  [ read more about DBM 620 ](/en-AU/measuring-instruments/portable-instruments/airflow-meters/dbm-620) [![DBM 620 Balometer](/sites/default/files/styles/medium/public/images/DBM620-1_1.jpg?itok=yrwC_FGV)](/en-AU/measuring-instruments/portable-instruments/airflow-meters/dbm-620)

#### DBM 620

Air Flow Meter

The newly redesigned Sauermann DBM 620 Air Flow Meter is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings from air vents.



 

 [ read more about AMI 310 ](/en-AU/measuring-instruments/portable-instruments/multifunctions/ami-310) [![ami310](/sites/default/files/styles/medium/public/images/ami310.jpg?itok=hqLZSHF6)](/en-AU/measuring-instruments/portable-instruments/multifunctions/ami-310)

#### AMI 310

Multifunction

Kimo’s AMI 310 measures simultaneous parameters including pressure, temperature (Pt100 and thermocouple), humidity, air quality (CO/CO2), air velocity, airflow (vane probes and hotwire), and tachometry.



 

 [ read more about Airflow cones ](/en-AU/measuring-instruments/portable-instruments/accessories/airflow-cones) [![Compo_Si-K25_Si-K85](/sites/default/files/styles/medium/public/images/Compo_Si-K25_Si-K85.png?itok=AnL8Tsxk)](/en-AU/measuring-instruments/portable-instruments/accessories/airflow-cones)

#### Airflow cones

For vane anemometers

The Si-K25 and Si-K85 are airflow measurement cones designed for 100 mm diameter vane anemometers. These models feature a honeycomb-structured airflow straightener that reduces turbulence for more reliable flow measurement.

The Si-K25 and Si-K85 are perfectly suited to Kimo [LV 110](https://sauermanngroup.com/en-AU/node/78/) and [LV 130](https://sauermanngroup.com/en-AU/node/79/), [VT 210](https://sauermanngroup.com/en-AU/node/86/), [MP 210](https://sauermanngroup.com/en-AU/node/87/) and [AMI 310](https://sauermanngroup.com/en-AU/node/88/) [anemometers](https://sauermanngroup.com/en-AU/taxonomy/term/16).

The Si-K85 square cone can be used with medium-sized air vents.  
The Si-K25 round cone is designed for small and medium-sized round vents.

|  | ![Si-K25](/sites/default/files/inline-images/Si-K25_face_0.png) | ![Si-K85](/sites/default/files/inline-images/Si-K85_3.png) |
|---|---|---|
| ##### Designation | ##### Si-K25 (28111) | ##### Si-K85 (28112) |
| ##### Flow | ###### 10 to 400 m3/h | ###### 10 to 400 m3/h |
| ##### Internal dimensions | ###### Ø 260 mm | ###### 350 x 350 mm |
| ##### External dimensions | ###### L 282 x W 282 x H 268 mm | ###### L 372 x W 372 x H 327 mm |



 



      ![Sauermann DBM 620](/sites/default/files/styles/max_1300x1300/public/images/SOLUTION-22_Produits-03_699x393.png?itok=SrJ0sWsH) 

 

 

 



    Metrological follow-up    ## Metrological follow-up

The use of suitable, certified equipment is essential to guarantee the quality of the services provided in these demanding environments. Metrological traceability to national standards of the equipment used is therefore an essential guarantee of reliability.

The connected calibration certificates issued by Sauermann are drawn up in accordance with the FD X07-12 standard governing metrology for businesses. The certifications are carried out in our laboratories and assure users that their measurements are reliable, enabling them to carry out their work with complete confidence.



 [Our services](https://sauermanngroup.com/en-GB/services)

 

      ![Sauermann Services](/sites/default/files/styles/max_1300x1300/public/images/SOLUTION-22_Produits-04_699x393.png?itok=cjJQZ5Zv) 

 

 

 



  



##  Products and accessories 

 [ ![sonde-helice](/sites/default/files/styles/event_thumb_max_200w/public/images/vitesse-2014-only.jpg.webp?itok=mBZkkk2P)

 

#### For class 210 / 310 multi-function portables

 

###  Air velocity vane probes 

 Kimo's vane probes measure air velocity and temperature. They have a variety of measuring ranges depending on the vane diameter.

 

 Read more 

 

 ](/en-AU/measuring-instruments/portable-instruments/probes/air-velocity-vane-probes)

 [ ![sonde-vitesse](/sites/default/files/styles/event_thumb_max_200w/public/images/sondes-vitesse-fil-chaud.png.webp?itok=nyp5PiPa)

 

#### For class 210 / 310 multi-function portables

 

###  Air velocity hot wire probes 

 Kimo`s hot wire probes measure air velocity and temperature.

 

 Read more 

 

 ](/en-AU/measuring-instruments/portable-instruments/probes/air-velocity-hot-wire-probes)

 [ ![sonde-hygro](/sites/default/files/styles/event_thumb_max_200w/public/images/hygro-2014.jpg.webp?itok=hFkhvgu6)

 

#### For class 210 / 310 multi-function portables

 

###  Hygrometry probes 

 Kimo's hygrometry probes measure humidity, dew point, and temperature.

 

 Read more 

 

 ](/en-AU/measuring-instruments/portable-instruments/probes/hygrometry-probes)

 

 








 ![France](/sites/default/files/styles/thumbnail/public/images/Fichier%202%404236x.png?itok=2qUd9mwj)

## In-House

Our two main factories  
Our customer service  
Our metrology laboratories  
Our Research &amp; Development team



 



 ![45 years of experience](/sites/default/files/styles/thumbnail/public/images/45Years_EN_8.png?itok=KnqDAzVa)

## 45 years of experience

For over 45 years, the Sauermann Group has been designing, manufacturing and marketing products and services dedicated to the HVACR and industrial markets.



 



 

[Information, quotes: I'd like to be contacted by phone](/en-AU/contact)